English translation with original Hindi content of 11.3 Corner Compound Wall of building located on a turn (intersection) of the Jaipur building bye laws 2020

11.0 Internal Standards Required for Building Construction

11.3 Corner Compound Wall of building located on a turn (intersection) –

(i) In the corner section of the boundary/wall, at the intersection of the road, the height of the wall will be limited to 0.75 meters for a length of 5 meters on both sides of the turn and the remaining height can be completed by installing a railing.

(ii) In case of a dangerous or inconvenient turn (intersection) on the road, the local authority will have the right to instruct the owner of the building on the corner or boundary wall at the turn to make it round-shaped, as deemed appropriate by the local authority.

11.3. मोड़ (नुक्कड़) पर स्थित भवन की दीवार (Corner Compound Wall)-

 (i) कोने के भूखण्ड में सीमाभिती/ दीवार की ऊंचाई सड़क के मोड़ पर, मोड़ से सामने और पार्श्व में दोनों ओर 5 मी. की लम्बाई में 0.75 मी. तक सीमित रहेगी और शेष ऊंचाई रेलिंग लगाकर पूरी का जा सकेगी।

(ii) सड़क पर खतरनाक अथवा असुविधाजनक मोड (नुक्कड) होने पर स्थानीय निकाय को नुक्कड़ के भवन के स्वामी को यह निर्देश देने का अधिकार होगा कि वह भवन के नुक्कड को अथवा मोड़ पर बाउण्ड्री की दीवार को ऐसा गोलाकार बना दे, जैसा कि स्थानीय निकाय द्वारा ठीक समझा जावे।

11.4 Stairs and Corridor

11.5. Lift, Escalator and Mechanical Car Lift

Building Bye laws home page : Jaipur building bye laws 2020

Download PDF

Register & Download PDF for Educational Purposes Only

JDA BUILDING BYE LAWS 2020.pdf

 Latest Amendment in Rajasthan Building Bye Laws 29 Nov 2022-fd.pdf

Register as member and login to download attachment [pdf] by right-click the pdf link and Select “Save link as” use for Educational Purposes Only

FD Planning Community Forum Discussion

Disclaimer

The translation may not be an exact word-to-word translation but is an attempt to convey the meaning accurately. Information on this site is purely for education purpose. The materials used and displayed on the Sites, including text, photographs, graphics, illustrations and artwork, video, music and sound, and names, logos, IS Codes, are copyrighted items of respective owner. Front Desk is not responsible and liable for information shared above

2 thoughts on “Regulation 11.3 Corner Compound Wall of building located on a turn – Jaipur building bye laws 2020

Leave a Reply

Your email address will not be published. Required fields are marked *