TOILETS / SANITATION REQUIREMENT for Hostels

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirements :

For Residents and Residential Staff : For Male : 1 per 8 persons or part thereof 
For Residents and Residential Staff : For Female  : 1 per 6 persons or part thereof 

To Read more…  TOILETS REQUIREMENTS for Hostels.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENTS for Schools and Educational Institutions

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirements : 
Nursery Schools  : 1 per 15 pupils(students) or part thereof 
Educational institutions (Non Residential) : For Boys : 1 per 40 pupils(students) or part thereof 
Educational institutions (Non Residential) : For Girls : 1 per 25 pupils(students) or part thereof 
Educational institutions (Residential) : For Boys : 1 per 8 pupils (students) or part thereof 
Educational institutions (Residential) : For Girls : 1 per 6 pupils (students) or part thereof 

To Read more…  TOILETS REQUIREMENTS for Schools and Educational Institutions.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENT for Restaurants

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirements

For Male public :  1 for 50 seats up to 200 seats; and for over 200 seats, add at the rate of 1 per 100 seats or part thereof
For Female public :  1 for 50 seats up to 200 seats; and for over 200 seats, add at the rate of 1 per 100 seats or part thereof

For Male Staff :          1 for 1 to 15 persons

2 for 16 to 35 persons
                                  3 for 36 to 65 persons
                                  4 for 66 to 100 persons…..

For Female Staff :  1 for 1 to 12 persons
                                     2 for 13 to 25 persons
                                     3 for 26 to 40 persons
                                     4 for 41 to 57 persons…….

To Read more… TOILETS REQUIREMENTS for Restaurants.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENTS for Art galleries , libraries and museums

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirements

For male public : 1 Per 200 persons up to 400 persons and for over 400 persons add at the rate of 1 per 250 persons or part thereof
For Female public : 1 Per 100 persons up to 200 persons and for over 200 persons add at the rate of 1 per 150 persons or part thereof

To Read more… TOILETS REQUIREMENTS for Art galleries , libraries and museums.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENT for office building

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirement

For male personnel : 1 for every 25 persons or part thereof
For Female personnel : 1 for every 15 persons or part thereof

To Read more… TOILETS REQUIREMENTS for office building.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENT for Hotel

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirements

For residential Public Staff : 1 per 8 persons omitting occupants of the room with attached water closets ; minimum of 2 if both sexes are lodged 

For public rooms (male) : 1 per 100 persons up to 400 persons and for over 400, add at the rate of 1 per 250 persons or part thereof 

To Read more… TOILETS REQUIREMENTS for Hotels.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENTS for Factories 

as par Indian Standards IS 1172 : 1993

Water closet (WC) Requirements : 
For Male personnel : 1 for 1 to 15 persons
                                  2 for 16 to 35 persons
                                  3 for 36 to 65 persons
                                  4 for 66 to 100 persons…..

For Female personnel : 1 for 1 to 12 persons

                                     2 for 13 to 25 persons
                                     3 for 26 to 40 persons
                                     4 for 41 to 57 persons…….

To Read more… TOILETS REQUIREMENTS for Factories.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENTS for Hospitals
Indoor and Outdoor Patient Wards
Administrative Buildings, Medical Staff Quarters and Nurses’ Homes

as per Indian Standards IS 1172 : 1993

Water closet (WC) Requirement
Indoor Patient Wards ( For Males and Females) : 1 for every 8 beds or part thereof

Wash basins Requirement : 
Indoor Patient Wards ( For Males and Females) : 2 up to 30 beds; add 1 for every additional 30 beds or part thereof

To Read more… TOILETS REQUIREMENTS for Hospitals, Indoor and Outdoor Patient Wards.pdf

TOILETS REQUIREMENTS for Hospitals ( Administrative Buildings, Medical Staff Quarters and Nurses’ Homes).pdf

Register in Front Desk Architects & Planners Forum to download above PDF

TOILETS / SANITATION REQUIREMENTS for Cinemas, Concert Halls and Theaters

as per IS 1172 : 1993

Water closets (WC) requirements : 
Male public : 1 per 100 persons up to 400 persons; and for over 400 persons,add at the rate of 1 per 250 persons or part thereof
Female public : 3 per 100 persons up to 200 persons; and for over 200 persons add at the rate of 2 per 100 persons or part thereof
Male staff : 1 for 1 to 15 persons 2 for 16 to 35 persons
Female staff : 1 for 1 to 12 persons 2 for 13 to 25 persons

To Read more… TOILETS REQUIREMENTS for Cinemas, Concert Halls and Theaters.pdf

Register in Front Desk Architects & Planners Forum to download above PDF

Forum Threads

TOILETS REQUIREMENTS for Hostels
TOILETS REQUIREMENTS for Schools and Educational Institutions
TOILETS REQUIREMENTS for Restaurants
TOILETS REQUIREMENTS for Art galleries , libraries and museum
TOILETS REQUIREMENTS for office building
TOILETS REQUIREMENTS for Hotels
TOILETS / SANITATION REQUIREMENTS for Factories
TOILETS REQUIREMENTS for Hospitals
TOILETS REQUIREMENTS for Cinemas, Concert Halls and Theaters

Disclaimer

Information on this site is purely for education purpose. The materials used and displayed on the Sites, including text, photographs, graphics, illustrations and artwork, video, music and sound, and names, logos, IS Codes, are copyrighted items of respective owners. Front Desk is not responsible and liable for information shared above.

1 thought on “TOILETS / SANITATION Requirement as per Indian Standards

Leave a Reply

Your email address will not be published. Required fields are marked *